ezi-Fiber Quick Assembly LC Connectors

Brand: DINTEK
You Can Request Pricing By Building Up An RFP:

Available Options

* LC Connector Type:

DINTEK’s ezi-FIBERTM Mechanical LC Connectors provide an inexpensive, & efficient tooless alternative to terminating fibers without the need for a fusion splicer. 
DINTEK’s ezi-FIBERTM LC Connectors use V-groove technology, to align the fibers together and maintain physical contact between the fibers. No assembly tool is required to ensure the fibers are mated correctly. The resulting connection using the connector results in an average insertion loss of
about 0.1dB.

 

Applications

◻  FTTx
◻  Pigtail connection in premise environments
◻  (FTTx) applications
◻  Telecommunications
◻  CATV
◻  Local area network

Benefits
◻  Minimal tools required
◻  Fast splicing time
◻  For 250 µm and/or 900 µm buffered fibers
◻  Uses V-Groove alignment technology
◻  30 Second Termination Time
◻  Connectors Are Re-usable
◻  Insertion loss of approx 0.1dB
◻  Can be joined to make duplex, triplex etc.

Termination Process

Step 1
◻  Remove Dust Cap and clean Ferrule. Connect QLC with fiber VFL to verify connections.

 

Step 3
◻  Take off Release Key & Turn on the VFL checker light.

 

 

Step 5
◻  Slide on correct boot, and screw cover. Prepare fiber as below.

Strip,clean & cleave fiber precisely.

 

How to re-use it the connector
◻  Insert Releasey Key back to release the metal Button, then remove fiber.

 

Making It Duplex and Triplex 
◻  Clamp connectors side by side to create multi configurations.

Step 2
◻  Slide on correct boot, and screw cover. Prepare fiber as below. Strip,clean & cleave fiber precisely.

 

Step 4
◻  Remove Dust Cap and clean Ferrule. Connect QLC with fiber VFL to verify connections.

 

Step 6
◻  Take off Release Key & Turn on the VFL checker light.

 

 

Terminating a 3.0mm Cable
◻  Insert fiber as shown above. Cut strength member after locking Boot.


ezi-Fiber LC Quick Assembly Connectors

Applications

  • FTTx
  • Pigtail connection in premise environments
  • Fiber-to-the-Subscriber (FTTx) applications
  • Telecommunications
  • CATV
  • Local area network



Standards

  • ISO/IEC 11801
  • Cenelec EN 50173-1 / TIA-568 C.0
  • Data Center Cenelec EN 50173-5
  • ISO/IEC 24764/ TIA-942
  • Ethernet IEEE 802.3; 10/40/100GbE



Features

  • Minimal tools required
  • Low insertion loss of between 0.1-0.2dB
  • Environmentally stable
  • Easy termination / Fast splicing time
  • Suitable for 250 μm and/or 900 μm buffered fibers
  • Uses V-Groove alignment technology

Benefits

Fast splicing time

Uses V-Groove alignment technology

Connectors are Re-usable

Can be joined to make duplex, triplex etc.




ezi-FIBER LC Connectors

The ezi-FIBER LC connector range comes in various options including OM1, OM2, OM3, OM4 and OS2



Fiber Accommodations 

250um / 900um / 2.0mm / 3.0 mm








Ordering Information
Product NumberProduct NameConnector TypeColorMode

2106-02014

ezi-FIBER LC/UPC SM Quick Assembly Connector

LC/UPC

Blue

Single Mode

2106-02015

ezi-FIBER LC/APC SM Quick Assembly Connector

LC/APC

Green

Single Mode

2106-02016

ezi-FIBER LC MM Quick Assembly Connector (50/125)

LC

Beige

Multi Mode

2106-02017

ezi-FIBER LC MM Quick Assembly Connector (62.5/125)

LC

Beige

Multi Mode

2106-02018

ezi-FIBER LC MM Quick Assembly Connector (OM3)

LC

Aqua

Multi Mode

2106-02019

ezi-FIBER LC MM Quick Assembly Connector (OM4)

LC

Aqua

Multi Mode


Technical Specifications

General Specifications
Cable Size250um / 900um / 2.0mm / 3.0 mm
Assembly Time30 seconds (after preparing fiber ends)
MaterialsEngineering Plastics & Index matching gel
Mechanical Data
Pull Strength (kg), Typical0.5kgf (900um); 6kgf (3.0mm)
Operating Temperature (deg)-40 ~ +80°C
Connector Length41mm
Performance Data
Insertion Loss (dB), Typical0.1dB Insertion Loss (dB)
Insertion Loss (dB), MaximumMax 0.2dB
Return Loss (dB), Typical-50 ~ -55dB

Termination Process



Remove Dust Cap and clean Ferrule. Connect QLC with fiber VFL to verify connections.



Slide on correct boot, and screw cover. Prepare fiber as below. Strip and clean it. Cleave fiber precisely.



Take off Release Key & Turn onthe checker.



Insert fiber to LC Connector until it touches the fiber inside.



Form a small curve. Then, press metal Button to connect fibers. You will see no leakage of red light for a low loss



Lock Boot and Wear Dust Cap.
Now the connection is complete.



How to re-use Connector | Insert the connector Insert release key. Press down to release the metal Button.



How to connect a 3.0mm cable. | Insert fiber as shown above. Cut strength member after locking Boot.